| Electronic Components Datasheet Search |
|
LDLL16ENTR Datasheet(PDF) 14 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LDLL16ENTR Datasheet(HTML) 14 Page - STMicroelectronics |
|
14 / 102 page ![]() • V3V3 < V3V3_POR_L – RAM content reloaded with shadow register content – Device will reach fail-safe state with GSB.RSTB = 1, to inform the application about the reason of this transition 4.2 Programmable functions 4.2.1 Direct drive and functional configuration Output channels assignement The LDLL16EN features 1 direct input pin (DIN). Each output can be assigned to DIN or to none by 1 dedicated FTP bit (DIN_MAP_CHx, see the Section 6: FTP and RAM memory mapping) per output channel, as showed in Table 3. Table 3. Output channel mapping to DIN DIN_MAP_CHx <0> Output Channel Status 0 OUTx NOT mapped (Group 0) 1 OUTx mapped on DIN (Group 1) In fail-safe/stand-alone mode, the outputs are always controlled by DIN - according to the assignment defined in Table 3, except the case when the channel is programmed permanently ON by dedicated FTP bits (FS_OUTx_EN <0>, see the Section 6: FTP and RAM memory mapping). When this bit is set, the related output channel “x” is permanently active in fail-safe/stand-alone mode regardless of the DIN, see Table 4. Table 4. Output channel in fail-safe/stand-alone mode FS_OUTx_EN <0> Output channel status 0 OUTx according to DIN_MAP_CHx <0> 1 OUTx permanently ON In case the channel is configured ON in fail-safe/stand-alone mode, a configurable delay of the output activation after power on reset (tPOR_DELAY) prevents any undesired flashing while configuring the devices and entering normal/bus mode. In other words, after power on reset, all outputs are kept off till power on reset delay time elapses to prevent any flashing during the time needed to enter in bus mode operation. In normal/bus mode, the direct inputs access to outputs can be enabled/disabled for each channel. If enabled (DIN_EN), bus control is applied when DIN = 0. If DIN is set (DC or PWM) the bus control is automatically disabled (after elapsing of tFILTER) and overtaken by DIN (the direct inputs have priority versus bus control). Bus control is re-established upon tBUS_CONTROL elapse after last falling edge on DIN. For DIN, a read-back information is available. It is forecasted one status bit (DIN_STATUS <0>, see the Section 6: FTP and RAM memory mapping) to support functional safety. The LDLL16EN features also 1 VPREG pin to supply the anode of the LED strings through an external pre- regulator. LDLL16EN Functional description DS14111 - Rev 5 page 14/102 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |