12 / 36 page ![]() SA56004X_5 © NXP B.V. 2008. All rights reserved. Product data sheet Rev. 05 — 22 May 2008 12 of 36 NXP Semiconductors SA56004X Digital temperature sensor with overtemperature alarms 7.9 Interruption logic and functional description 7.9.1 ALERT output The ALERT output is used to signal Alert interruptions from the device to the SMBus or other system interrupt handler and it is active LOW. Because this is an open-drain output, a pull-up resistor (typically 10 k Ω) to V DD is required. Several slave devices can share a common interrupt line on the same SMBus. The ALERT function is very versatile and accommodates three separate operating modes: • Temperature comparator • System interrupt based on temperature • SMBus Alert Response Address (ARA) response. The ARA and interrupt modes are different only in how the user interacts with the SA56004X. At the end of every temperature reading, digital comparators determine if the readings are above the HIGH or T_CRIT setpoint or below the LOW setpoint register values. If so, the corresponding bit in the Status register is set. If the ALERT mask bit 7 of the Configuration register is not HIGH, then any bit set in the Status register other than the BUSY (D7) and OPEN (D2) will cause the ALERT output pin to be active LOW. An alert will be triggered after any conversion cycle that finds the temperature is out of the limits defined by the setpoint registers. In order to trigger an ALERT in all alert modes, the ALERT mask bit 7 of the Configuration register must be cleared (not HIGH). 7.9.1.1 ALERT output in comparator mode When operating the SA56004X in a system that utilizes an SMBus controller not having an interrupt, the ALERT output may be operated as a temperature comparator. In this mode, when the condition that triggered the ALERT to be asserted is no longer present, the ALERT output is released as it goes HIGH. In order to use the ALERT output as a temperature comparator, bit D0 (the ALERT configure bit) in the ALERT Mode (AM) register must be set HIGH. This is not the POR default. 7.9.1.2 ALERT output in interrupt mode In the interrupt mode, the ALERT output is used to provide an interrupt signal that remains asserted until the interrupt service routine has elapsed. In the interrupt operating mode, a read of the Status register will set the ALERT mask bit 7 of the Configuration register if any of the temperature alarm bits of the Status register is set, with exception of BUSY (D7) and OPEN (D2). This protocol prevents further ALERT output triggering until the master device has reset the ALERT mask bit at the end of the interrupt service routine. The Status register bits are cleared only upon a read of the Status register by the serial bus master (see Figure 5). In order for the ALERT output to be used as an interrupt, the ALERT Configure bit D0 of the ALERT Mode (AM) register must be set LOW (POR default). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |