| Electronic Components Datasheet Search |
|
SA56004GD Datasheet(PDF) 22 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
SA56004GD Datasheet(HTML) 22 Page - NXP Semiconductors |
|
22 / 36 page ![]() SA56004X_5 © NXP B.V. 2008. All rights reserved. Product data sheet Rev. 05 — 22 May 2008 22 of 36 NXP Semiconductors SA56004X Digital temperature sensor with overtemperature alarms 10. Characteristics [1] The SA56004X is optimized for 3.3 V VDD operation. [2] Definition of Under Voltage Lockout (UVL): The value of VDD below which the internal A/D converter is disabled. This is designed to be a minimum of 200 mV above the power-on reset. During the time that it is disabled, the temperature that is in the ‘read temperature registers’ will remain at the value that it was before the A/D was disabled. This is done to eliminate the possibility of reading unexpected false temperatures due to the A/D converter not working correctly due to low voltage. In case of power-up (rising VDD), the reading that is stored in the ‘read temperature registers’ will be the default value of 0 °C. V DD will rise to the value of the UVL, at which point the A/D will function correctly and the normal temperature will be read. [3] VDD (rising edge) voltage below which the A/D converter is disabled. [4] VDD (falling edge) voltage below which the logic is reset. Table 18. Electrical characteristics VDD = 3.0 V to 3.6 V; Tamb = −40 °C to +125 °C; unless otherwise specified. Symbol Parameter Conditions Min Typ Max Unit TERRL local temperature error Tamb = +60 °C to +100 °C −2 ±1+2 °C Tamb = −40 °C to +125 °C −3- +3 °C TERRR remote temperature error Tamb = +25 °C to +85 °C; TRD = +60 °C to +100 °C −1- +1 °C Tamb = −40 °C to +85 °C; TRD = −40 °C to +125 °C −3- +3 °C TRESR remote temperature resolution - 11 - bit - 0.125 - °C TRESL local temperature resolution - 11 - bit - 0.125 - °C Tconv conversion period - 38 - ms VDD supply voltage [1] 3.0 - 5.5 V IDD quiescent current during conversion, 16 Hz conversion rate - 500 - µA shut-down current SMBus inactive - 10 - µA IRD remote diode source current high setting: D+ − D− = +0.65 V - 160 - µA low setting - 10 - µA UVL UnderVoltage Lockout (UVL) threshold voltage[2] VDD input disables A/D conversion [3] 2.6 - 2.95 V Power-On Reset (POR) threshold voltage VDD input falling edge [4] 1.8 - 2.4 V local and remote ALERT high default temperature settings default values set at power-up - +70 - °C local and remote ALERT low default temperature settings default values set at power-up - 0 - °C local and remote T_CRIT default temperature settings default values set at power-up - +85 - °C T_CRIT hysteresis default value set at power-up - +10 - °C ALERT and T_CRIT output saturation voltage IO = 6.0 mA - - 0.4 V |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |