67 / 111 page ![]() IS25WP064A/032A Integrated Silicon Solution, Inc.- www.issi.com 67 Rev. 00D 03/01/2016 8.28 CLEAR EXTENDED READ REGISTER OPERATION (CLERP, 82h) A Clear Extended Read Register (CLERP) instruction clears PROT_E, P_ERR, and E_ERR error bits in the Extended Read Register to “0” when the error bits are set to “1”. Once the error bits are set to “1”, they remains set to “1” until they are cleared to “0” with a CLERP command. Figure 8.48 Clear Extended Read Register Sequence In SPI Mode Instruction = 82h CE# SCK SI 0 1 2 3 4 5 6 7 Mode 3 Mode 0 SO High Impedance Figure 8.49 Clear Extended Read Register Sequence In QPI Mode 82h CE# SCK IO[3:0] 0 1 Mode 3 Mode 0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|