| Electronic Components Datasheet Search |
|
WM8803CDT/V Datasheet(PDF) 23 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8803CDT/V Datasheet(HTML) 23 Page - Wolfson Microelectronics plc |
|
23 / 45 page ![]() Product Preview WM8803 w PP Rev 1.1 September 2003 23 status data delimiter bit 1. In this case, the parity error flag used for data recognized as PCM data will not be output. OTHER ERRORS Even when ERROR has gone low, the WM8803 always acquires bits 24 to 27 (sampling frequency) of the channel status and compares the current data with that of the previous block. If any differences are found, ERROR is immediately set to the high level and the state is handled as a PLL lock error. Similarly, when FLIMIT is set to restrict fs input range and the input fs calculation results are reflected in the error flags, fs calculation results are compared continuously. If a disparity occurs in the data, ERROR will immediately go high, and the state will be handled as a PLL lock error. ERROR OCCURRENCE PROCESSING This section describes the data processing performed when an error occurs. When up to 8 consecutive input parity errors occur and if the transmitted data is PCM audio data, the data is replaced with the corresponding left and right channel data from the immediately preceding frame. If the transmitted data is non-PCM data, the error data is output without modification. Non-PCM data is based on data that was detected before the input parity error that occurred, and is data for which the channel status bit 1 non-PCM data detection bit is “1”. The output data is muted when 9 or more consecutive parity errors, or a PLL lock error, occur. For the channel status output when a parity error occurs, the data for the previous block is retained. DATA AND DETECTION FLAGS PLL LOCK ERROR INPUT PARITY ERROR (A) INPUT PARITY ERROR (B) INPUT PARITY ERROR (C) SDATO output pin L L Previous data Output Input fs calculation L L Output Output Channel status data L L Previous data Previous data Sub-code Q data L L Output — Table 10 Data Processing when Errors Occur Notes: 1. Input parity error (A): When 9 or more consecutive parity errors occur 2. Input parity error (B): When up to 8 consecutive parity errors occur in audio data 3. Input parity error (C): When up to 8 consecutive parity errors occur in non-PCM burst data The figure below presents an example of the data processing performed when a parity error occurs. ERROR SDATAO R-ch Previous data value Input Data LRCLK An error occurs a single time Muted after 9 or more consecutive errors L-ch R-ch …. Previous data value R-2 L-2 R-0 L-1 R-0 L-0 L-2 R-2 L-2 R-2 L-2 R-2 L-2 R-2 L-4 R-3 L-3 R-2 L-2 R-1 R-4 L-5 R-5 L-6 R-6 L-7 R-7 L-8 R-8 L-1 Figure 18 Data Processing Example Following a Parity Error (When PCM data is received) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |