  K3HB-R Datasheet HTML 1Page - Omron Electronics LLC K3HB-R Datasheet HTML 2Page - Omron Electronics LLC K3HB-R Datasheet HTML 3Page - Omron Electronics LLC K3HB-R Datasheet HTML 4Page - Omron Electronics LLC K3HB-R Datasheet HTML 5Page - Omron Electronics LLC K3HB-R Datasheet HTML 6Page - Omron Electronics LLC K3HB-R Datasheet HTML 7Page - Omron Electronics LLC K3HB-R Datasheet HTML 8Page - Omron Electronics LLC K3HB-R Datasheet HTML 9Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 17 page
background image
5
K3HB-R
F3
Error ratio
Multiplies the error between input A and input B
(
−1) by 100 and displays the ratio as a percentage
(%).
Display unit: %
Measuring the line speed error ratio between two conveyors
F4
Rotational
difference
Displays the difference between input A and input B
(B
− A) as the rotation (rpm) speed error or
circumferential speed error.
Display unit:
rpm, rps, rph,
Hz, kHz, mm/s, m/s
m/min, km/h
l/min, l/h, etc.
Measuring the rotation (rpm)/circumferential speed error (absolute error)
between two conveyors
F5
Flow rate
ratio
Displays the flow rate ratio of B from inputs A and B
(
) as a ratio (%).
Display unit: %
Monitoring liquid mixture flow rate ratio
F6
Passing
time
The passing time for the desired distance is displayed
by measuring the frequency of input A.
Passing time (s) = 1/ƒa
×
α
ƒa: Input frequency (Hz)
Set the prescale value for the desired display unit using
the following table for reference.
N = Pulses per rotation
πd = Circumferential length per rotation (m)
L = Length of process (m)
Display unit:
Seconds (s), minutes (min),
hours/minutes/seconds (h.min.s),
minutes/seconds/tenths of seconds
(min.s.1/10s), etc.
Displaying the passing time for a conveyor line
Function
Operation
Operation image (application)
B
A
Communications
output
(remote monitoring)
To computer
⎛
⎜
⎜
⎜
⎜
⎝
⎞
⎟
⎟
⎟
⎟
⎠
H
HH
PASS
L
LL
Warning
B
A+B
Linear output
Recording meter
Calculation
Display unit Prescale value (
α)
Passing time
s
L/(
πd/N)
⎛
⎜
⎜
⎜
⎜
⎝
⎞
⎟
⎟
⎟
⎟
⎠
H
PASS
L
Warning
output
Distance



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link to Datasheet   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com