28 / 52 page ![]() 9.6 Clamp-On Ultrasonic Flow Meter Figure 9-6 shows how ultrasonic flow meters measure the rate of flow of a liquid using transit-time difference (t12–t21), which depends on the flow rate. Figure 9-6 shows a representative schematic for a non-intrusive ultrasonic flow meter using the OPAx863 devices and 12-V transducer excitation. The OPAx863 devices are used for the forward path as a unity-gain buffer for 12-V pulsed transducer excitation at Node 1. At the same time, the receiver circuit at Node 2 (which also uses the OPAx863 devices) first provides an AC-gain followed by a DC-level shift to lead to the PGA, ADC, and processor within the MSP430 microcontroller. Node 2 and Node 1 use similar transmit and receive circuits (discussed previously) for the reverse path. The OPAx863 devices wide GBW of 50 MHz introduces minimal phase-delay and low-noise for superior flow rate measurement. The amplifier stays in power-down mode for a majority of the time in battery powered systems, resulting in very small average system-level power consumption and prolonged battery lifetime with its 1.5 µA (maximum) power-down mode quiescent current with a 3-V supply. Since the transmit and receive signal chains are connected to the same point at the respective node transducers, the OPAx863's 12.6-V supply voltage capability enables 12-V transducer excitation without any damage to the front-end or need for external switches which makes a compact solution. This makes the OPAx863 devices suitable for flow measurements in large diameter pipes and non-intrusive flow meters. The TIDM-02003 reference design discusses an ultrasonic gas flow sensing subsystem which uses high-speed amplifiers for front-end amplification. TR X1 + ± OP Ax863 12 V R ISO + ± R F R G C G C Filt C AC2 R¶ R¶ 3.3 V PGA ADC MSP430FR6043 OP Ax863 TR X2 Processor Transmitter Receiver Receiver Transmitter NODE-1 NODE-2 3.3 V 12 V 0 V 12 V V TX 0 V 12 V V TX V R X V R X t 12 t 21 R R C AC1 12 V Figure 9-6. Non-Intrusive Ultrasonic Flow Meter OPA863, OPA2863, OPA4863 SBOS982I – JUNE 2020 – REVISED DECEMBER 2022 www.ti.com 28 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated Product Folder Links: OPA863 OPA2863 OPA4863 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |