847 / 1158 page ![]() Section 16 USB Function Module (USB) Rev.1.00 Jun. 07, 2006 Page 795 of 1102 REJ09B0294-0100 16.5.4 Control Transfer Control transfer consists of three stages: setup, data (not always included), and status (figure 16.9). The data stage comprises a number of bus transactions. Operation flowcharts for each stage are shown below. Control-in Setup stage Data stage Status stage Control-out No data SETUP(0) DATA0 SETUP(0) DATA0 SETUP(0) DATA0 IN(1) DATA1 OUT(1) DATA1 IN(0) DATA0 OUT(0) . . . . . . DATA0 IN(0/1) DATA0/1 OUT(0/1) DATA0/1 OUT(1) DATA1 IN(1) DATA1 IN(1) DATA1 Figure 16.9 Transfer Stages in Control Transfer |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|