4 / 23 page ![]() www.sensirion.com / D1 Version 3.3 – November 2024 4 / 23 1.1.1 Total accuracy calculation: Total typical accuracy = ±(Base Accuracy + cC * ΔC + cT * ΔT + cRH * ΔRH + cP * ΔP) 1.1.2 Example for accuracy calculation: Product initialized and sensor FRC performed at conditions: 400 pm CO2 (0.04%), 20°C, 50%RH, 1000 mbar. Sensor target conditions for measurement: 10 vol% CO2 in a cold (0°C) and dry (10% RH) environment with possible elevation up to 2000 m and 800 mbar. Accuracy is calculated by assuming worst case scenarios for each parameter: Typical base accuracy: 0.2 vol% = 0.2 vol% additional concentration error: cC * ΔC = 0.02 vol% * (10% – 0.04%) = 0.2 vol% additional temperature error: cT * ΔT = 0.02 vol% * (20 – 0) = 0.4 vol% additional RH error: cRH * ΔRH = 0.01 vol% * (50% – 10%) = 0.4 vol% additional pressure error: cP * ΔP = 0.001 vol% * (1000 – 800) = 0.2 vol% Total typical accuracy = 0.2 + 0.2 + 0.4 + 0.4 + 0.2 = ±1.4 vol% 1.2 Low-noise measurement mode specifications The following specifications for the low-noise measurement mode are adopted without change from the STC31 Datasheet V1.1 and are still valid for the new “C” version of the STC31-C. The new standard low-cross-sensitivity measurement mode is the recommended mode for most applications; however, the low-noise mode might offer some advantages in specific cases. See also the revision notice in section 7 and unit of measurement in section 1.1. Low-noise measurement mode Parameter Value Calibrated for8 CO2 in N2 and CO2 in air9 Measurement range10 0 to 25 vol% 0 to 100 vol% Span Accuracy11 0.5 vol% + 3% measured value 1 vol% + 3% measured value Noise12 < 0.2 vol% Temperature stability13 0.025 vol% / °C Resolution 16 bit Response time (τ63) < 0.5 s 8 Specifications are only valid for these binary gas mixtures (air is interpreted as being one type of gas). 9 Air is defined as 78.1 vol% nitrogen, 21.0 vol% oxygen and 0.9 vol% argon. 10 Measurement mode and range can be chosen by setting the gas model as described in 3.3.2 11 Accuracy is defined after performing FRC at 0 vol% providing a correct temperature, humidity, and pressure measurement. Consult sections 3.3.3, 3.3.4, 3.3.5 and 3.3.7. for detailed information. Fulfilled by 90% of sensors after calibration. 12 Error given for the statistical 2σ range, i.e. 95% of consecutive measurements. Smoothing filters available on chip, see Section 3.3.9. 13 Slope of CO2 accuracy tolerance after correct temperature compensation when changing temperature compared to the temperature at which the FRC has been performed. Fulfilled by 90% of sensors after calibration. Valid for the temperature range of 0 – 50°C. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |