| Electronic Components Datasheet Search |
|
SMARTSTART-BDC-C Datasheet(PDF) 13 Page - IDEC Corporation |
|
|
|||||||||||||||||||||||||||||
SMARTSTART-BDC-C Datasheet(HTML) 13 Page - IDEC Corporation |
|
13 / 14 page ![]() IDEC SmartRelay General Information www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC H-13 H Maximum Setup • High-speed/Optimal Communication Performance For optimal and high-speed communication performance between the IDEC SmartRelay and the various modules, we recommend you install the digital modules first, then the analog modules (see example above). Setup With Different Voltage Classes • Rules Digital modules can only be connected to devices of the same voltage class. • Overview: Connecting an expansion module to IDEC SmartRelay • Overview: Connecting an additional expansion module to an expansion module I/O Configuration with LONWORKS® Communication Module Module Combination and Allocation Numbers 1. Maximum number of I/O points using LONWORKS® communication module 2. Using analog inputs on the base module 3. Using expansion I/O modules Base module, LONWORKS® communication module, Combination I/O module, Analog input module CPU Expansion Modules M08B2R2 M08B1S2 M08D2R2 M08C2R2 J2B2 AS-i/LON FL1C-H12RCE X X X – X X FL1C-H12SND X X X – X X FL1C-H12RCA X X X – X X FL1C-H12RCC – – – X X X FL1C-B12RCE X X X – X X FL1C-B12RCA X X X – X X FL1C-B12RCC – – – X X X Expansion Module Additional Expansion Modules M08B2R2 M08B1S2 M08D2R2 M08C2R2 J2B2 CAS2 CL1C12 FL1B-M08B2R2 X X X – X X X FL1B-M08B1S2 X X X – X X X FL1B-M08D2R2 X X X – X X X FL1B-M08C2R2 – – – X X X X FL1B-J2B2 X X X – X X X FL1B-CAS2 AS-Interface X X X–X– – FL1B-CL1C12 LONWORKS –––––– – FL1C-H12RCC FL1B-CL1C12 Digital Input:I 12345678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Analog Input:AI 1 2 3 4 5 6 7 8 Digital Output:Q 1234 5 6 7 8 9 10 11 12 13 14 15 16 FL1C-H12RCE FL1B-CL1C12 Digital Input:I 1 2 3 4 5 678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Analog Input:AI 1 2 3 4 5 6 7 8 Digital Output:Q 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FL1C-H12RCE FL1B-M08B2R2 FL1B-CL1C12 Digital Input:I 1 2 3 4 5 678 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Analog Input:AI 1 2 3 4 5 6 7 8 Digital Output:Q 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FL1B-J2B2 General Information • Maximum Setup of IDEC SmartRelay With Analog Inputs FL1C-H12RCE/B12RCE/H12SND (CPU, 4 digital modules and 3 analog modules) I1.....I6, I7, I8 AI1, AI2 CPU Q1,,,Q4 I9...I12 FL1B- M08B2R2 Q5...Q8 I13...I16 FL1B- M08B2R2 Q9...Q12 I17...I20 FL1B- M08B2R2 Q13...Q16 I21...I24 FL1B- M08B2R2 AI3, AI4 FL1B- J2B2 AI5, AI6 FL1B- J2B2 AI7, AI8 FL1B- J2B2 • Maximum Setup of IDEC SmartRelay Without Analog Inputs FL1C-H12RCA/B12RCA/H12RCC/B12RCC (CPU, 4 digital modules and 4 analog modules) I1. . . . . . . . I8 CPU Q1,,,Q4 I9...I12 FL1B-M08 Q5...Q8 I13...I16 FL1B-M08 Q9...Q12 I17...I20 FL1B-M08 Q13...Q16 I21...I24 FL1B-M08 AI1, AI2 J2B2 AI3, AI4 J2B2 AI5, AI6 J2B2 A17, A18 J2B2 1. The LONWORKS® communication module can be used with any base module and expansion I/ O module. 2. The LONWORKS® communication module must be mounted at the right-most position of the row. 3. I/O numbers are automatically allocated start- ing with the base module. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |