  1041648 Datasheet HTML 1Page - SICK AG 1041648 Datasheet HTML 2Page - SICK AG 1041648 Datasheet HTML 3Page - SICK AG 1041648 Datasheet HTML 4Page - SICK AG 1041648 Datasheet HTML 5Page - SICK AG 1041648 Datasheet HTML 6Page - SICK AG 1041648 Datasheet HTML 7Page - SICK AG 1041648 Datasheet HTML 8Page - SICK AG 1041648 Datasheet HTML 9Page - SICK AG  
Zoom Inzoom in Zoom Outzoom out
 7 / 9 page
background image
S31A-7011CA | S3000 Cold Store
SAFETY LASER SCANNERS
Protective field switching with two static inputs
12
16
7
6
3
5
15
11
14
13
8
4
+24 V DC Scanner
+24 V DC Heating
0 V DC Heating
In A
H2
H8
K1
K2
In B
0 V DC Scanner
1)
k1
k1
k2
k2
z
z
x
y
x
y
E112711/00/2014-03-06
S3000
Cold Store
S3000 Cold Store with S3000 Cold Store in conjunction with relays/contactors
Protective field switching by means of control input A and control input B on separate OSSD pairs (simultaneous monitoring)
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
S3000 Cold Store in conjunction with relays/contactors
Protective field switching by means of control inputs A and B
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2017-05-23 16:45:04 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
7



Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link to Datasheet   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com