| Electronic Components Datasheet Search |
|
LUCL9500AGF-DT Datasheet(PDF) 23 Page - Agere Systems |
|
|
|||||||||||||||||||||||||||||
LUCL9500AGF-DT Datasheet(HTML) 23 Page - Agere Systems |
|
23 / 32 page ![]() Preliminary Data Sheet September 2001 High-Voltage Ringing SLIC for VoIP Applications L9500A Agere Systems Inc. 23 Applications (continued) Battery Reversal Rate The rate of battery reverse is controlled or ramped by capacitors FB1 and FB2. A chart showing FB1 and FB2 values vs. typical ramp time is given below. Leave FB1 and FB2 open if it is not desired to ramp the rate of bat- tery reversal. Table 20. FB1 and FB2 Values vs. Typical Ramp Time Supervision The L9500 offers the loop closure and ring trip supervi- sion functions. Internal to the device, the outputs of these detectors are multiplexed into a single package output (NSTAT). The ring trip detector is valid on NSTAT during the ring mode and loop closure detector is valid on NSTAT during active and on-hook transmis- sion modes. Additionally, common-mode current is detected for ground start applications. This status is output onto NSTAT and is valid during ground start mode. Loop Closure The loop closure has a fixed typical 10.5 mA on- to off- hook threshold in the active mode and a fixed 11.5 mA on- to off-hook threshold from the scan mode. In either case, there is a 2 mA hysteresis with VCC = 5 V and a 2 mA hysteresis with VCC = 3.3 V. Ring Trip The ring trip detector requires only a single-pole filter at the input, minimizing external components. An R/C combination of 383 k Ω and 0.1 µF, for a filter pole at 5.15 Hz, is recommended. The ring trip threshold is internally fixed as a function of battery voltage and is given by: RT (mA) = 67 * {(0.0045 * VBAT1) + 0.317} where: RT is ring trip current in mA. VBAT1 is the magnitude of the ring battery in V. There is a 6 mA to 8 mA hysteresis. Ground Start In the ground start applications, the loop closure detec- tor detector is also used to indicate that ring-ground has occurred. During ground start mode, loop current will be common mode, rather than differential as in loop start mode. Thus, in ground start the threshold of the loop closure detector is reduced by one half the thresh- old seen in the loop start mode.This ouput is seen at the NSTAT output pin. CFB1 and CFB2 Transition Time 0.01 µF 20 ms 0.1 µF 220 ms 0.22 µF 440 ms 0.47 µF 900 ms 1.0 µF 1.8 s 1.22 µF2.25 s 1.3 µF 2.5 s 1.4 µF 2.7 s 1.6 µF 3.2 s |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |