| Electronic Components Datasheet Search |
|
AHF2803DF/HB Datasheet(PDF) 3 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
AHF2803DF/HB Datasheet(HTML) 3 Page - International Rectifier |
|
3 / 19 page ![]() www.irf.com 3 AHF28XX Series Table I. Electrical Performance Characteristics - continued 1. Parameter guaranteed by line and load regulation tests. 2. Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz. 3. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on. 4. Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in Table I. 5. An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 6. Load step transition time between 2.0 µs and 10µs. 7. Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1.0 percent of V OUT at 50 percent load. 8. Input step transition time between 2.0 µs and 10µs. 9. Turn-on delay time measurement is for either a step application of power at the input or the removal of ground signal from the inhibit pin (pin 1) while power is applied to the input is unlimited. Notes to Specifications AHF2803R3S Test Symbol Conditions Group A Device Unit -55°C ≤ Tc ≤ +125°C Subgroups Types Vin = 28Vdc ±5%, CL = 0 Unless otherwise specified Min Max 50% to/from 100% rated load 0% to/from 50% rated load 50% to/from 100% rated load 4,5,6 70 µs 0% to/from 50% rated load 4,5,6 1200 µs 50% to/from 0% rated load 4,5,6 8.0 ms Input step 16V to/from 40Vdc, IOUT = 100% 4,5,6 500 mVpk rated load 4, 8 Input step 16V to/from 40Vdc, IOUT = 100% 4,5,6 800 µs rated load 4, 7, 8 Turn on overshoot VTonOS IOUT = o and 100% rated load 4,5,6 01 600 mVpk Turn on delay TonD IOUT = o and 100% rated load 9 4,5,6 01 20 ms Load fault recovery 4, 9 Weight 38 g 01 Output response to transient step line changes VOTLINE 01 Output response to step transient load changes 6 VOTLOAD Recovery time step transient load changes 6, 7 TTLOAD +300 -500 +500 mVpk Limits Recovery time transient step line changes TTLINE 01 4,5,6 4,5,6 01 -300 ms TrLF 4,5,6 01 20 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |