3 / 6 page ![]() Solid State Pressure Sensors D8M 3 Operation ■ Response Timing Charts D8M-D82 Legend: T1, Pressure measurement time T2, Response time T3, Electrical discharge time D8M-R1 ■ Interface Circuit Diagram D8M-R1 Response time to 90% of 0.2kPa Max. 3 seconds (excluding time for pressure change) Application Examples Compact D8M solid state pressure sensors provide reliable detection for gas and air inflow for burner controls in water heaters, furnaces and other gas-fired devices. They can also be used in gas usage meters. Model T1T2T3 D8M-D82 1.5 ms min. 30 ms max. 45 ms max. Response time to 90% of 0.2kPa Max. 3 seconds (excluding time for pressure change) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|