| Electronic Components Datasheet Search |
|
E5CD-RX2ABM-000 Datasheet(PDF) 11 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CD-RX2ABM-000 Datasheet(HTML) 11 Page - Omron Electronics LLC |
|
11 / 56 page ![]() E5CD/E5CD-B 11 USB-Serial Conversion Cable Windows is a registered trademark of Microsoft Corporation in the United States and or other countries. *1. CX-Thermo version 4.65 or higher runs on Windows 10. *2. Use a high-power port for the USB port. Note: A driver must be installed on the computer. Refer to the Instruction Manual included with the Cable for the installation procedure. Communications Specifications * The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications Setting Level. Communications Functions MELSEC is a registered trademark of Mitsubishi Electric Corporation. KEYENCE is a registered trademark of Keyence Corporation. *Programless communications supports the copying function. Current Transformer (Order Separately) Ratings Heater Burnout Alarms and SSR Failure Alarms *1. For heater burnout alarms, the heater current will be measured when the control output is ON, and the output will turn ON if the heater current is lower than the set value (i.e., heater burnout detection current value). *2. For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output will turn ON if the heater current is higher than the set value (i.e., SSR failure detection current value). *3. The value is 30 ms for a control period of 0.1 s or 0.2 s. *4. The value is 38 ms for a control period of 0.1 s or 0.2 s. Electrical Life Expectancy Curve for Control Output Relay (Reference Values) Applicable OS Windows XP/Vista/7/8/10 *1 Applicable software CX-Thermo version 4.66 or higher (E5CD-B: version 4.67 or higher) Applicable models E5 @C-T Series, E5@C Series, E5CB Series, and E5 @D Series USB interface standard Conforms to USB Specification 2.0. DTE speed 38,400 bps Connector specifications Computer: USB (type A plug) Digital Temperature Controller: Special serial connector Power supply Bus power (Supplied from USB host controller.) *2 Power supply voltage 5 VDC Current consumption 450 mA max. Output voltage 4.7 ±0.2 VDC (Supplied from USB-Serial Conversion Cable to the Digital Temperature Controller.) Output current 250 mA max. (Supplied from USB-Serial Conversion Cable to the Digital Temperature Controller.) Ambient operating temperature 0 to 55°C (with no condensation or icing) Ambient operating humidity 10% to 80% Storage temperature −20 to 60°C (with no condensation or icing) Storage humidity 10% to 80% Altitude 2,000 m max. Weight Approx. 120 g Transmission line connection method RS-485: Multidrop Communications RS-485 (two-wire, half duplex) Synchronization method Start-stop synchronization Protocol CompoWay/F, or Modbus Baud rate * 9,600, 19,200, 38,400, 57,600, or 115,200 bps Transmission code ASCII Data bit length * 7 or 8 bits Stop bit length * 1 or 2 bits Error detection Vertical parity (none, even, odd) Block check character (BCC) with CompoWay/F or CRC-16 Modbus Flow control None Interface RS-485 Retry function None Communications buffer 217 bytes Communications response wait time 0 to 99 ms Default: 20 ms Programless communications You can use the memory in the PLC to read and write E5CD/E5CD-B parameters, start and stop operation, etc. The E5CD/E5CD-B automatically performs communications with PLCs. No communications programming is required. Number of connected Digital Temperature Controllers: 32 max. (Up to 16 for the FX3) Applicable PLCs OMRON PLCs CS Series, CJ Series, CP Series, NJ Series, or NX1P Mitsubishi Electric PLCs MELSEC Q Series, L Series, FX3 Series, or iQ-R Series KEYENCE PLCs KEYENCE KV Series Copying * When Digital Temperature Controllers are connected, the parameters can be copied from the Digital Temperature Controller that is set as the master to the Digital Temperature Controllers that are set as slaves. E54-CT1 E54-CT3 E54-CT1L E54-CT3L Dielectric strength 1,000 VAC for 1 min 1,500 VAC for 1 min Vibration resistance 50 Hz, 98 m/s2 Weight E54-CT1: Approx. 11.5 g E54-CT3: Approx. 50 g E54-CT1L: Approx. 14 g E54-CT3L: Approx. 57 g Accessories E54-CT3 Only Armatures (2) Plugs (2) None CT input (for heater current detection) Models with detection for single-phase heaters: One input Maximum heater current 50 A AC Input current indication accuracy ±5% FS ±1 digit max. Heater burnout alarm setting range *1 0.1 to 49.9 A (in units of 0.1 A) Minimum detection ON time: 100 ms *3 SSR failure alarm setting range *2 0.1 to 49.9 A (in units of 0.1 A) Minimum detection OFF time: 100 ms *4 500 300 100 50 30 10 5 3 1 0 12345 6 Switching current (A) E5CD 250 VAC, 30 VDC (resistive load) cosφ = 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |