| Electronic Components Datasheet Search |
|
PAXUSB Datasheet(PDF) 11 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
PAXUSB Datasheet(HTML) 11 Page - Red Lion Controls. Inc |
|
11 / 32 page ![]() 11 5.0 reviewing The frOnT buTTOns and display Counter Readout Legends* Setpoint Alarm Annunciators RST DSP PAR F1 F2 A C B SP1 SP3 SP2 SP4 8.8.8.8.8.8 KEY DISPLAY MODE OPERATION PROGRAMMING MODE OPERATION DSP Index display through the selected displays. Quit programming and return to Display Mode PAR Access Programming Mode Store selected parameter and index to next parameter F1 Function key 1; hold for 3 seconds for Second Function 1 ** Increment selected parameter value or selections F2 Function key 2; hold for 3 seconds for Second Function 2 ** Decrement selected parameter value or selections RST Reset (Function key) *** Advances digit location in parameter values * Counters B, and C are locked out in Factory Settings (PAXC and PAXI only). ** Factory setting for the F1, and F2 keys is NO mode. *** Factory setting for the RST key is (Reset Display). PROGRAMMING MODE ENTRY (PAR KEY) The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing the PAR key. If it is not accessible then it is locked by either a security code, or a hardware lock. Two types of programming modes are available. Quick Programming Mode permits only certain parameters to be viewed and/or modified. All meter functions continue to operate except the front panel keys change to Programming Mode Operations. Quick Programming Mode is configured in Module 3. Full Programming Mode permits all parameters to be viewed and modified. In this mode, incoming counts may not be recognized correctly, the front panel keys change to Programming Mode Operations and certain user input functions are disabled. Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming. MODULE ENTRY (ARROW & PAR KEYS) The Programming Menu is organized into nine modules. These modules group together parameters that are related in function. The display will alternate between and the present module. The arrow keys (F1 and F2) are used to select the desired module. The displayed module is entered by pressing the PAR key. MODULE MENU (PAR KEY) Each module has a separate module menu (which is shown at the start of each module discussion). The PAR key is pressed to advance to a particular parameter to be changed, without changing the programming of preceding parameters. After completing a module, the display will return to . Programming may continue by accessing additional modules. SELECTION / VALUE ENTRY (ARROW & PAR KEYS) For each parameter, the display alternates between the present parameter and the selections/value for that parameter. The arrow keys (F1 and F2) are used to move through the selections/values for that parameter. Pressing the PAR key, stores and activates the displayed selection/value. This also advances the meter to the next parameter. For numeric values, the RST key may be used to select a specific digit to be changed. Once a digit is selected, the arrow keys are used to increment or decrement that digit to the desired number. PROGRAMMING MODE EXIT (DSP KEY or at PAR KEY) The Programming Mode is exited by pressing the DSP key (from anywhere in the Programming Mode) or the PAR key (with displayed). This will commit any stored parameter changes to memory and return the meter to the Display Mode. If a parameter was just changed, the PAR key should be pressed to store the change before pressing the DSP key. (If power loss occurs before returning to the Display Mode, verify recent parameter changes.) PROGRAMMING TIPS It is recommended to start with Module 1 for counting and Module 4 for rate. If lost or confused while programming, press the DSP key and start over. When programming is complete, it is recommended to record the parameter programming on the Parameter User Chart and lock out parameter programming with a user input or lock-out code. FACTORY SETTINGS Factory Settings may be completely restored in Module 9. This is a good starting point for programming problems. Most parameters can be left at their Factory Settings without affecting basic start-up. ALTERNATING SELECTION DISPLAY In the explanation of the modules, the following dual display with arrows will appear. This is used to illustrate the display alternating between the parameter on top and the parameter’s Factory Setting on the bottom. In most cases, selections and values for the parameter will be listed on the right. 6.0 prOgramming The meTer Parameters Input Rate 4-rtE Parameters & B Input 1-INP Pro DISPLAY MODE Lock-out Key 2-FNC Parameters 3-LOC Parameters Function Program Communication (Alarm) Counter C 6-SPt 5-CtrC 7-SrL Parameters Setpoint*Serial* Service Output 9-FCS 8-AnA Parameters Factory Analog* Parameters Parameters Operations Counter A User Input/ NO * Only accessible with appropriate option card. PAR F1/F2 Keys Display/ PAR PAR PAR PAR PAR PAR PAR PAR PAR OVERVIEW PROGRAMMING MENU Indicates Program Mode Alternating Display Factory Settings are shown. Parameter Selection/Value Shaded areas represent program access that is model dependent. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |