| Electronic Components Datasheet Search |
|
SHT41-AD1B-R3 Datasheet(PDF) 10 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SHT41-AD1B-R3 Datasheet(HTML) 10 Page - Sensirion AG Switzerland |
|
10 / 17 page ![]() www.sensirion.com / D1 Version 2 – July 2021 10/17 4.4 Command Overview Command (hex) Response length incl. CRC (bytes) Description [return values] 0xFD 6 measure T & RH with high precision (high repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0xF6 6 measure T & RH with medium precision (medium repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0xE0 6 measure T & RH with lowest precision (low repeatability) [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x89 6 read serial number [2 * 8-bit data; 8-bit CRC; 2 * 8-bit data; 8-bit CRC] 0x94 - soft reset [ACK] 0x39 6 activate heater with 200mW for 1s, including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x32 6 activate heater with 200mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x2F 6 activate heater with 110mW for 1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x24 6 activate heater with 110mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x1E 6 activate heater with 20mW for 1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] 0x15 6 activate heater with 20mW for 0.1s including a high precision measurement just before deactivation [2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC] Table 7 Overview of I2C commands. If the sensor is not ready to process a command, e.g. because it is still measuring, it will response with NACK to the I2C read header. Given heater power values are typical and valid for VDD=3.3V. 4.5 Conversion of Signal Output The digital sensor signals correspond to following humidity and temperature values: ������������ = (−6 + 125 ∙ ������������������ 216 − 1 ) %RH ( 1 ) ������ = (−45 + 175 ∙ ������������ 216 − 1 ) °C ( 2 ) ������ = (−49 + 315 ∙ ������������ 216 − 1 ) °F ( 3 ) N.B.: The RH conversion formula (1) allows values to be reported which are outside of the range of 0 %RH … 100 %RH. Relative humidity values which are smaller than 0 %RH and larger than 100 %RH are non-physical, how ever these “uncropped” values might be found beneficial in some cases (e.g. when the distribution of the sensors at the measurement boundaries are of interest). For all users who do not want to engage in evaluation of these non-physical values, cropping of the RH signal to the range of 0 %RH … 100 %RH is advised. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |