| Electronic Components Datasheet Search |
|
JUA-R Datasheet(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
JUA-R Datasheet(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 5 page ![]() MODEL: JUA JUA SPECIFICATIONS ES-1660 Rev.10 Page 3/5 https://www.m-system.co.jp/ • DC Voltage: 0 – 11.5 V DC Minimum span: 4 V Offset: Max. 1.5 times span Load resistance: Output drive 1 mA max. (Output: Load resistance) 0 – 10 V : 10 k (Ω min.) 0 – 5 V : 5000 1 – 5 V : 5000 ■ Alarm Output: Relay contact Rated load: 120 V AC @ 0.5 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 0.5 A (resistive load) Maximum switching voltage: 380V AC or 125 V DC (To conform with EU Directive, limit the voltage to 300 V AC (Measurement Category I) or 150 V AC (Measurement Category II) or less.) Maximum switching power: 120 VA or 30 W (≤ 0.5 A) Minimum load: 5 V DC @ 10 mA Mechanical life: 5 × 107 cycles For maximum relay life with inductive loads, external protection is recommended. Alarm Trip Example (Hi/Lo) Terminal No. in parentheses Trip Operation in Power Failure : Terminals 1 – 2, 9 – 10 turn ON. 0 50 100 Input (%) Lo Setpoint Hi Setpoint Hi Output (Output 1) (9–15)ON Lo Output (Output 2) (1–2)ON (1–11)ON (9–10)ON INSTALLATION Power input • AC: Operational voltage range: rating ±10 %, 50/60 ± 2 Hz, approx. 2.5 VA •DC: Operational voltage range: rating ±10 % ripple 10 %p-p max., approx. 2.5 W (105 mA at 24 V) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lb) PERFORMANCE in percentage of span •DC input Accuracy: ±0.1 % •Thermocouple input Accuracy: ±0.3 % Linearization accuracy: ±0.05 % Cold junction compensation error: ±0.5°C or ±0.9°F max. (at 20°C ±10°C or 68°F ±18°F) Burnout response: ≤ 10 sec. •RTD input Accuracy: ±0.1% or ±0.1°C, whichever is greater (±0.3 % for 2-wire RTD) Burnout response: ≤ 10 sec. •Potentiometer input Accuracy: ±0.1 % Setting accuracy: ±0.3 % + input specific accuracy Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) (±0.03 %/°C or ±0.01 %/°F for 2-wire RTD) Response time: ≤ 0.5 sec. (0 – 90 %) (≤ 0.7 sec. for RTD inputs) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 min. (input to DC output to alarm output to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (alarm output) Installation Category II (power) Pollution degree 2 Input or DC output or alarm output to power: Reinforced insulation (300 V) Input to DC output to alarm output: Basic insulation (300 V) RoHS Directive |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |