3 / 6 page ![]() 2 Noise measurements The VIPer122 frequency jittering feature allows the spectrum to be spread over frequency bands rather than being concentrated on single frequency value. Especially when measuring conducted emission with the average detection method, the level reduction can be several dBµV. A pre-compliance test for the EN55022 (Class B) European normative was performed and the average measurements of the conducted noise emissions at full load and nominal mains voltages are shown in the following figures. Figure 3. CE average measurement at 115 VAC full load Figure 4. CE average measurement at 230 VAC full load STEVAL-VP12201F Noise measurements DB4121 - Rev 1 page 3/6 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|