Frequency Parameters
Frequency 10.0MHz
Frequency Tolerance ±1.00ppm
Frequency Stability ±0.05ppm
Operating Temperature Range -40.00 to 105.00°C
Ageing ±0.01ppm max per day, ±1ppm
max/year
Frequency Tolerance (measurement referenced to frequency
observed with TA=25°C, Vs=3.3V, within 30 days after
ex-works)
Frequency Stability: TA varied across the operating
temperature range, measurement referenced to frequency
observed with TA=25°C, Vs=3.3V, load=15pF and temperature
variable speed less than 2°C per minute.
Ageing: TA=25°C, Vs= 3.3V and after 1hr of operation.
Supply Voltage Variation (measurement referenced to
frequency observed with TA=25°C, Vs varied from 3.13V to
3.47V and load=15pF): ±0.05ppm max
Load Variation (5% load change measurement referenced to
frequency observed with TA=25°C, Vs=3.3V and load= 15pF):
±0.05ppm max
|