## FNQ-R-7: Technical Overview
The **FNQ-R-7** is a high-performance, time-delay fuse belonging to the **Limitron™** family, manufactured by **Bussmann (Eaton)**. It is specifically designed as a "CC Class" fuse, which is one of the most common standards for branch circuit protection in industrial environments.
---
### 1. Key Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Model Number** | FNQ-R-7 |
| **Amperage Rating** | 7 Amps |
| **Voltage Rating (AC)** | 600 Vac (or less) |
| **Interrupting Rating** | 200,000 Amps RMS Symmetrical |
| **Fuse Class** | Class CC |
| **Response Characteristic** | Time-Delay (Slow Blow) |
| **Physical Dimensions** | 13/32" x 1-1/2" (10.3 x 38.1 mm) |
| **Material** | Melamine tube with nickel-plated brass endcaps |
---
### 2. Electronic Characteristics & Functionality
#### A. Rejection Feature
The "R" in the part number denotes a **rejection tip**. Class CC fuses have a unique physical groove on one end. This ensures that:
* Standard non-rejection fuses cannot be inserted into a Class CC holder.
* The circuit is guaranteed the high interrupting rating and protection level intended by the design.
#### B. Time-Delay Mechanism
Unlike "Fast-Acting" fuses, the FNQ-R-7 is engineered to withstand short-duration **inrush currents**.
* **Inductive Loads:** It is ideal for small motors and transformers that pull a high surge of current upon startup.
* **Nuisance Tripping:** It prevents the fuse from blowing during normal operational spikes while still protecting against sustained overloads and short circuits.
#### C. High Current Limitation
The FNQ-R-7 is highly current-limiting. In the event of a catastrophic short circuit, it reacts in less than half a cycle to "cut off" the peak current, protecting sensitive downstream components like contactors or solid-state relays.
---
### 3. Common Applications
The FNQ-R-7 is typically found in industrial control panels and machinery. Primary use cases include:
1. **Control Transformers:** Protecting the primary side of industrial control transformers.
2. **Solanoids:** Handling the inductive kickback and startup draw.
3. **Small Motor Branch Circuits:** Providing specialized protection where space is limited but high interrupting capacity is required.
---
### 4. Comparison to Similar Fuses
| Fuse Type | Characteristic | Best For |
| :--- | :--- | :--- |
| **FNQ (Midget)** | Supplemental, Time-Delay | General purpose, no rejection tip. |
| **FNQ-R (Class CC)** | Branch Circuit, Time-Delay | High safety requirements, motor/transformer protection. |
| **KTK-R (Class CC)** | Fast-Acting | Resistive loads, lighting, no inrush current. |
- ⤷
What is the difference between a Midget fuse and a Class CC fuse in terms of safety ratings?
- ⤷ How do I calculate if a 7-amp time-delay fuse is sufficient for my motor's inrush current?
- ⤷ Are there specific fuse holders required for the rejection tip on the FNQ-R-7?