9 / 19 page 1.0 Functional Description (Continued) 1.3 FUNCTION AND INITIALIZATION LATCHES Both the function and initialization latches write to the same registers. (See Section 1.7.1 DEVICE PROGRAMMING AFTER FIRST APPLYING V CC section for initialization latch description.) TABLE 1. Programmable Modes C1 C2 F1 F2 F3–5 F6 F7 F8 0 1 COUNTER POWER DOWN FoLD PD CP FASTLOCK RESET CONTROL POLARITY TRI-STATE ENABLE F9 F10 F11–14 F15–F17 F18 FAST- TIMEOUT TIMEOUT TEST POWER LOCK COUNTER COUNTER MODES DOWN CONTROL ENABLE VALUE MODE TABLE 2. Mode Select Truth Table REGISTER LEVEL COUNTER RESET POWER DOWN PHASE CP TRI-STATE DETECTOR POLARITY 0 RESET POWERED NEGATIVE NORMAL DISABLED UP OPERATION 1 RESET POWERED POSITIVE TRI-STATE ENABELED DOWN FUNCTION DESCRIPTION F1. The Counter Reset enable mode bit F1, when activated, allows the reset of both N and R counters. Upon powering up, the F1 bit needs to be disabled, then the N counter resumes counting in “close” alignment with the R counter. (The maximum error is one prescalar cycle). F2. Refer to Section 1.3.1 POWERDOWN OPERATION section. F3–5. Controls output of FoLD pin. See FoLD truth table. See Table 4. F6. Phase Detector Polarity. Depending upon VCO characteristics, F6 bit should be set accordingly. When VCO characteristics are positive F6 should be set HIGH; When VCO characteristics are negative F6 should be set LOW F7. Charge Pump TRI-STATE is set using bit F7. For normal operation this bit is set to zero. F8. When the FastLock Enable bit is set the part is forced into one of the four FastLock modes. See description in Table 5, Fast- Lock Decoding. F9. The FastLock Control bit determines the mode of operation when in FastLock (F8 = 1). When not in FastLock mode, FL o can be used as a general purpose output controlled by this bit. For F9 = 1, FL o is HIGH and for F9 = 0, FLo is LOW. See Table 5 for truth table. F10. Timeout Counter Enable bit is set to 1 to enable the timeout counter. See Table 5 for truth table. F11–14. FastLock Timeout Counter is set using bits F11-14. Table 6 for counter values. F15–17. Function bits F15–F17 are for Test Modes, and should be set to 0 for normal use. F18. Refer to Section 1.3.1 POWERDOWN OPERATION section. DS100127-7 www.national.com 9 |
Similar Part No. - LMX2306 |
|
Similar Description - LMX2306 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |