2 / 4 page 408- 9414 Terminating Head 58063- 2 Rev B 2 of 4 Tyco Electronics Corporation Figure 2 Wire Wire Slot Slide Connector Into Feed Channel Power Unit (Ref) Connector Terminating Connector 4. Repeat Steps 2 and 3 until all applicable contacts are terminated. 5. Slide the connector out of the head in the direction of the arrow. 6. Inspect each terminated contact according to Figure 4. If any contact does not meet the requirements, DO NOT use the connector. Refer to Section 4 for adjustments. For application requirements for the connectors, refer to application specification 114--40002. For assembly procedure, refer to 408--6621 for all plastic connectors and 408--6645 for metal shell connectors. 4. ADJUSTMENTS 4.1. Wire Insertion Depth If the wire is inserted too deep or not deep enough in the contact after termination, adjust the wire insertion depth as follows: A. Pneumatic Power Units To avoid personal injury when using pneumatic power units, ALWAYS disconnect the air supply before making any adjustments. Increase the air pressure by 10 psi [69 kPa]. Repeat the termination and inspection procedure. Continue in this manner until the proper wire insertion depth is obtained or the air pressure is set to 70 psi [483 kPa]. If proper wire insertion depth is not obtained at 70 psi [483 kPa], return the air pressure to 40 psi [276 kPa] and follow Paragraph B. For pneumatic power units, it might be necessary to adjust either the air pressure or the adjuster (inserter rod). B. Manual and Electric Power Units To prevent personal injury when using electric power units, ALWAYS disconnect the electrical power supply before making any adjustments. 1. Remove the head from the power unit according to the instructions packaged with the power unit. Make sure to observe any cautions and dangers. 2. Turn the adjuster (inserter rod) one--sixth of a revolution clockwise if the wire is too deep in the contact, and counterclockwise if the wire is not deep enough in the contact. Refer to Figure 3. This will decrease or increase the wire insertion depth by approximately 0.20 mm [.008 in.]. 3. Install the head onto the power unit according to the instructions packaged with the power unit. Make sure to observe any cautions and dangers. Figure 3 Turn CLOCKWISE To Decrease Wire Insertion Depth Turn COUNTERCLOCKWISE To Increase Wire Insertion Depth Adjuster (Inserter Rod) Wire Insertion Depth Adjustment 4.2. Wire Guide If the connector cannot be inserted into the head, the connector is too loose in the head, or the connector housing is damaged after termination, refer to Figure 1, and adjust the wire guide as follows: 1. For pneumatic power units, disconnect the air supply. For electric power units, disconnect the electrical power supply. 2. Loosen the two screws on the wire guide. 3. Slide the wire guide until the connector fits properly in the head. 4. Finger--tighten the screws. 5. INSPECTION AND MAINTENANCE 5.1. Inspection Regular inspections should be performed by quality control personnel with a record of quality control inspections remaining with the personnel responsible NOTE i DANGER NOTE i DANGER |
Similar Part No. - 3--21028--2 |
|
Similar Description - 3--21028--2 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |