CY7C185
Document #: 38-05043 Rev. *A
Page 2 of 11
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65
°C to +150°C
Ambient Temperature with
Power Applied............................................. –55
°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[3] ............................................ –0.5V to +7.0V
DC Input Voltage[3]......................................... –0.5V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Ambient
Temperature
VCC
Commercial
0
°C to +70°C
5V
± 10%
Industrial
–40
°C to +85°C
5V
± 10%
Electrical Characteristics Over the Operating Range
7C185-15
7C185-20
Parameter
Description
Test Conditions
Min.
Max.
Min.
Max.
Unit
VOH
Output HIGH Voltage
VCC = Min., IOH = –4.0 mA
2.4
2.4
V
VOL
Output LOW Voltage
VCC = Min., IOL = 8.0 mA
0.4
0.4
V
VIH
Input HIGH Voltage
2.2
VCC +
0.3V
2.2
VCC +
0.3V
V
VIL
Input LOW Voltage[3]
–0.5
0.8
–0.5
0.8
V
IIX
Input Load Current
GND
≤ V
I ≤ VCC
–5
+5
–5
+5
µA
IOZ
Output Leakage
Current
GND
≤ V
I ≤ VCC,
Output Disabled
–5
+5
–5
+5
µA
IOS
Output Short
Circuit Current[4]
VCC = Max.,
VOUT = GND
–300
–300
mA
ICC
VCC Operating
Supply Current
VCC = Max.,
IOUT = 0 mA
130
110
mA
ISB1
Automatic
Power-Down Current
Max. VCC, CE1 ≥ VIH or CE2 ≤ VIL
Min. Duty Cycle = 100%
40
20
mA
ISB2
Automatic
Power-Down Current
Max. VCC, CE1 ≥ VCC – 0.3V,
or CE2 ≤ 0.3V
VIN ≥ VCC – 0.3V or VIN ≤ 0.3V
15
15
mA
Notes:
3.
Minimum voltage is equal to –3.0V for pulse durations less than 30 ns.
4.
Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.