6 / 14 page 6 G2R PCB Power Relay G 2 R ■Characteristics ● Standard Relays Note: The values here are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. *2. Measurement conditions: Rated operating voltage applied, not including contact bounce. *3. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *4. Value for quick-connect terminals. Double-winding Latching Relays Note: The values here are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. *2. Measurement conditions: Rated operating voltage applied, not including contact bounce. *3. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. ■Engineering Data Item Number of poles 1-pole 2-pole Contact resistance *1 30 m Ω max. 50 m Ω max. Operate time *2 15 ms max. Release time *2 AC: 10 ms max.; DC: 5 ms max. Max. operating frequency Mechanical 18,000 operations/hr Electrical 1,800 operations/hr Insulation resistance *3 1,000 M Ω min. Dielectric strength Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min Between contacts of different polarity - 3,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 200 m/s2 when energized; 100m/s2 when no energized Durability Mechanical AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) Electrical 100,000 operations min. (at 1,800 operations/hr under rated load) Ambient operating temperature -40°C to 70°C (with no icing) Ambient operating humidity 5% to 85% Weight Approx. 17 g (Approx. 20 g *4) Item Number of poles 1-pole 2-pole Contact resistance *1 30 m Ω max. 50 m Ω max. Set Time *2 20 ms max. Min. set pulse width 30 ms Reset Time *2 20 ms max. Min. reset pulse width 30 ms Max. operating frequency Mechanical 18,000 operations/hr Electrical 1,800 operations/hr Insulation resistance *3 1,000 M Ω min. (at 500 VDC) Dielectric strength Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min Between contacts of different polarity − 3,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Between set and reset coils 1,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction Set: 500m/s2 Armature OFF Reset: 200m/s2 Contact OFF Durability Mechanical 10,000,000 operations min (at 18,000 operations/hr) Electrical 100,000 operations min. (at 1,800 operations/hr under rated load) Ambient operating temperature -40°C to 70°C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 17 g ● Maximum Switching Capacity G2R-1, G2R-1A, G2R-1-T, G2R-1A-T G2R-1-E, G2R-1A-E G2R-1Z, G2R-1AZ G2R-1-H, G2R-1A-H, G2R-2, G2R-2A G2R-2-H, G2R-2A-H Flux Protection/Plug-in Relays Switching voltage (V) 50 10 5 1 0.5 0.1 0 5 10 20 30 50 100 500 AC resistive load DC resistive load AC inductive load (cos φ = 0.4) DC inductive load (L/R = 7 ms) AC inductive load (cos φ = 0.4) Switching voltage (V) 50 10 5 1 0.5 0.1 0 5 10 20 30 50 100 500 16 DC resistive load AC resistive load DC inductive load (L/R = 7 ms) Switching voltage (V) 50 10 5 1 0.5 0.1 0 5 10 20 30 50 100 500 AC resistive load DC resistive load DC inductive load (L/R = 7 ms) AC inductive load (cos φ = 0.4) Switching voltage (V) 50 10 5 1 0.5 0.1 0 5 10 20 30 50 100 500 AC inductive load (cos φ = 0.4) DC inductive load (L/R = 7 ms) DC resistive load AC resistive load Switching voltage (V) 50 10 5 1 0.5 0.1 0 5 10 20 30 50 100 500 AC resistive load AC inductive load (cos φ = 0.4) DC resistive load DC inductive load (L/R = 7 ms) |
Similar Part No. - G2R-K-1AZ4-TE |
|
Similar Description - G2R-K-1AZ4-TE |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |