15 / 27 page ![]() ADJUST eff 1.008 2088 N 2088 § · u ¨ ¸ © ¹ eff ADJUST 1.008 2088 2088 N § · u ¨ ¸ © ¹ = V V BE2 BE1 - hkT q ln I 2 I 1 TMP451 www.ti.com SBOS686 – JUNE 2013 η-Factor Correction Register The TMP451 allows for a different η-factor value to be used for converting remote channel measurements to temperature. The remote channel uses sequential current excitation to extract a differential VBE voltage measurement to determine the temperature of the remote transistor. Equation 1 describes this voltage and temperature. (1) The value η in Equation 1 is a characteristic of the particular transistor used for the remote channel. The power- on reset value for the TMP451 is η = 1.008. The value in the η-factor correction register may be used to adjust the effective η-factor according to Equation 2 and Equation 3. (2) (3) The η-factor correction value must be stored in twos complement format, yielding an effective data range from –128 to +127. The η-factor correction value is written to and read from pointer address 23h. The register power- on reset value is 00h, thus having no effect unless a different value is written to it. Table 7. η-Factor Range NADJUST BINARY HEX DECIMAL η 0111 1111 7F 127 0.950198 0000 1010 0A 10 1.003195 0000 1000 08 8 1.004152 0000 0110 06 6 1.005111 0000 0100 04 4 1.006072 0000 0010 02 2 1.007035 0000 0001 01 1 1.007517 0000 0000 00 0 1.008 1111 1111 FF –1 1.008483 1111 1110 FE –2 1.008967 1111 1100 FC –4 1.009935 1111 1010 FA –6 1.010905 1111 1000 F8 –8 1.011877 1111 0110 F6 –10 1.012851 1000 0000 80 –128 1.073837 Offset Register The offset register allows the TMP451 to store any system offset compensation value that might be observed from precision calibration. The value in the register is stored in the same format as the temperature result, and is added to the remote temperature result upon every conversion. Combined with the η-factor correction, this function allows for very accurate system calibration over the entire temperature range. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 15 Product Folder Links: TMP451 |
Similar Part No. - TMP451 |
|
Similar Description - TMP451 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |