11 / 60 page www.ti.com 4.3 Front Page Indicators and Functions TLV320AIC3104EVM Software Figure 2 illustrates the main screen of the EVM software. The indicators and buttons located above the tabbed section of the front page are visible regardless of which tab is currently being selected. At the top left of the screen is an Interface indicator. This indicator shows which interface is selected for controlling the TLV320AIC3104, either I2C or SPI. To the right of the Interface indicator is a group box called . This box indicates where the firmware being used is operating from—in this release, the firmware is on the USB-MODEVM, so the user should see USB-MODEVM in the box labeled Located On:. The version of the firmware appears in the Version box below this. To the right, the next group box contains controls for resetting the TLV320AIC3104. A software reset can be done by writing to a register in the TLV320AIC3104, and this is accomplished by pushing the button labeled Software Reset. The TLV320AIC3104 also may be reset by toggling a pin on the TLV320AIC3104, which is done by pushing the Hardware Reset button. CAUTION In order to perform a hardware reset, the RESET jumper (JMP19) must be installed and SW2-7 on the USB-MODEVM must be turned OFF. Failure to do either of these steps results in not generating a hardware reset or causing unstable operation of the EVM, which may require cycling power to the USB-MODEVM. Below the Firmware box, the Device Connected LED should be green when the EVM is connected. If the indicator is red, the EVM is not properly connected to the PC. Disconnect the EVM and verify that the drivers were correctly installed, then reconnect and try restarting the software. One the upper right portion of the screen, several indicators are located which provide the status of various portions of the TLV320AIC3104. These indicators are activated by pressing the Indicator Updates button below the Device Connected LED. These indicators, as well as the other indicators on this panel, are updated only when the software's front panel is inactive, once every 20ms. The ADC Overflow and DAC Overflow indicators light when the overflow flags are set in the TLV320AIC3104. Below these indicators are the AGC Noise Threshold Exceeded indicators that show when the AGC noise threshold is exceeded. To the far right of the screen, the Short Circuit Detect indicators show when a short-circuit condition is detected, if this feature has been enabled. Below the short-circuit indicators, the AGC Gain Applied indicators use a bar graph to show the amount of gain which has been applied by the AGC, and indicators that light when the AGC is saturated. SLAU218 – August 2007 TLV320AIC3104EVM and TLV320AIC3104EVM-PDK 11 Submit Documentation Feedback |
Similar Part No. - TSW-102-07-L-D |
|
Similar Description - TSW-102-07-L-D |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |