17 / 31 page HA16117F Series 17 Selection of External Constants If the reset duration necessary for the MPU to operate reliably at power-on is known, there is a simple procedure for selecting external constants, starting from the power-on reset time (t ON). START Set power-on reset time tON Set reset high time tRH Select external constant CF Check watchdog frequency range fH and fL External constant values • Decide reset low time (tRL) • Select external constant CR • Decide reset-clock off time (tOFF) • Select external constants R1 and R2 Figure 4 Procedure for Selecting External Constants Application Example SW CF 0.01 µF R1 510 k Ω R2 750 k Ω CR 0.1 µF Battery Microprocessor system 5 V regulator VCC VCC Tadj P-RUN HA16117F ACC CF GND CR PORT GND RES RES |
Similar Part No. - HA16117F |
|
Similar Description - HA16117F |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |