![]() |
Electronic Components Datasheet Search |
|
M29DW641F Datasheet(PDF) 36 Page - Numonyx B.V |
|
|
M29DW641F Datasheet(HTML) 36 Page - Numonyx B.V |
36 / 80 page ![]() Command interface M29DW641F 36/80 6.3.11 Verify Standard Protection mode command The Verify Standard Protection mode command reads the status of the Standard Protection mode Lock bit. If it is ‘1’, the device is in Standard Protection mode. 6.3.12 Set Non-Volatile Modify Protection bit command A block or group of blocks can be protected from program or erase by issuing a Set Non- Volatile Modify Protection bit command along with the block address. This command sets the Non-Volatile Modify Protection bit to ‘1’ for a given block or group of blocks. Six cycles are required to issue the command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the program command. 3. The fourth and fifth cycles select the address (see Table 11: Protection command addresses). 4. The last cycle verifies if the operation has been successful. If DQ0 is set to ’1’, the Non- Volatile Modify Protection bit has been successfully programmed. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. There must be a 100µs delay between the fourth and fifth cycles. The Non-Volatile Modify Protection bits are erased simultaneously by issuing a Clear Non- Volatile Modify Protection bits command except if the Lock-Down bit is set to ‘1’. The Non-Volatile Modify Protection bits can be set a maximum of 100 times. 6.3.13 Verify Non-volatile Modify Protection bit command The status of a Non-Volatile Modify Protection bit for a given block or group of blocks can be read by issuing a Verify Non-Volatile Modify Protection bit command along with the block address. 6.3.14 Clear Non-volatile Modify Protection bit command This command is used to clear all Non-Volatile Modify Protection bits. No specific block address is required. If the Lock-Down bit is set to ‘1’, the command will fail. Six cycles are required to issue a Clear Non-Volatile Modify Protection bits command: 1. The first two cycles are unlock cycles. 2. The third cycle issues the command. 3. The last three cycles verify if the operation has been successful. If DQ0 is set to ’1’, all Non-Volatile Modify Protection bits have been successfully cleared. If DQ0 is ‘0’, the operation has failed and the command must be re-issued. There must be a 12ms delay between the fourth and fifth cycles. 6.3.15 Set Lock bit command The Set Lock bit command individually sets the Lock bit to ‘1’ for a given block or group of blocks. If the Non-Volatile Lock bit for the same block or group of blocks is set, the block is locked regardless of the value of the Lock bit. (see Table 7: Block Protection status). |
Similar Part No. - M29DW641F |
|
Similar Description - M29DW641F |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |