4 / 16 page 4 LT1021 1021fc ELECTRICAL C C HARA TERISTICS LT1021-10 PARAMETER CONDITIONS MIN TYP MAX UNITS Output Voltage (Note 2) LT1021C-10 9.995 10.00 10.005 V LT1021B-10/LT1021D-10 9.950 10.00 10.050 V Output Voltage Temperature Coefficient (Note 3) TMIN ≤ TJ ≤ TMAX LT1021B-10 ● 2 5 ppm/ °C LT1021C-10/LT1021D-10 ● 5 20 ppm/ °C Line Regulation (Note 4) 11.5V ≤ VIN ≤ 14.5V 1.0 4 ppm/V ● 6 ppm/V 14.5V ≤ VIN ≤ 40V 0.5 2 ppm/V ● 4 ppm/V Load Regulation (Sourcing Current) 0 ≤ IOUT ≤ 10mA 12 25 ppm/mA (Note 4) ● 40 ppm/mA Load Regulation (Shunt Mode) 1.7mA ≤ ISHUNT ≤ 10mA 50 100 ppm/mA (Notes 4, 5) ● 150 ppm/mA Supply Current (Series Mode) 1.2 1.7 mA ● 2.0 mA Minimum Current (Shunt Mode) VIN is Open 1.1 1.5 mA ● 1.7 mA Output Voltage Noise (Note 6) 0.1Hz ≤ f ≤ 10Hz 6.0 µVP-P 10Hz ≤ f ≤ 1kHz 3.5 6 µVRMS Long Term Stability of Output Voltage (Note 7) ∆t = 1000Hrs Noncumulative 15 ppm Temperature Hysteresis of Output ∆T = ±25°C 5 ppm Note 1: Absolute Maximum Ratings are those values beyond which the life of a device may be impaired. Note 2: Output voltage is measured immediately after turn-on. Changes due to chip warm-up are typically less than 0.005%. Note 3: Temperature coefficient is measured by dividing the change in output voltage over the temperature range by the change in temperature. Separate tests are done for hot and cold; TMIN to 25°C and 25°C to TMAX. Incremental slope is also measured at 25 °C. Note 4: Line and load regulation are measured on a pulse basis. Output changes due to die temperature change must be taken into account separately. Package thermal resistance is 150 °C/W for TO-5 (H), 130°C/W for N and 150 °C/W for the SO-8. Note 5: Shunt mode regulation is measured with the input open. With the input connected, shunt mode current can be reduced to 0mA. Load regulation will remain the same. Note 6: RMS noise is measured with a 2-pole highpass filter at 10Hz and a 2-pole lowpass filter at 1kHz. The resulting output is full-wave rectified and then integrated for a fixed period, making the final reading an average as opposed to RMS. Correction factors are used to convert from average to RMS and correct for the non-ideal bandpass of the filters. Peak-to-peak noise is measured with a single highpass filter at 0.1Hz and a 2-pole lowpass filter at 10Hz. The unit is enclosed in a still-air environment to eliminate thermocouple effects on the leads. Test time is 10 seconds. Note 7: Consult factory for units with long term stability data. The ● denotes specifications that apply over the full operating temperature range, otherwise specifications are TA = 25°C. VIN = 15V, IOUT = 0, unless otherwise noted. |
Similar Part No. - LT1021DCS8-10 |
|
Similar Description - LT1021DCS8-10 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |