Electronic Components Datasheet Search |
|
TMP411 Datasheet(PDF) 11 Page - Burr-Brown (TI) |
|
|
TMP411 Datasheet(HTML) 11 Page - Burr-Brown (TI) |
11 / 25 page TMP411 SBOS383A − FEBRUARY 2007 www.ti.com 11 STATUS REGISTER The TMP411 has a Status Register to report the state of the temperature comparators. Table 4 shows the Status Register bits. The Status Register is read-only and is read by reading from pointer address 02h. The BUSY bit reads as ‘1’ if the ADC is making a conversion. It reads as ‘0’ if the ADC is not converting. The OPEN bit reads as ‘1’ if the remote transistor was detected as open since the last read of the Status Register. The OPEN status is only detected when the ADC is attempting to convert a remote temperature. The RTHRM bit reads as ‘1’ if the remote temperature has exceeded the remote THERM limit and remains greater than the remote THERM limit less the value in the shared Hysteresis Register; see Figure 17. The LTHRM bit reads as ‘1’ if the local temperature has exceeded the local THERM limit and remains greater than the local THERM limit less the value in the shared Hysteresis Register; see Figure 17. The LHIGH and RHIGH bit values depend on the state of the AL/TH bit in the Configuration Register. If the AL/TH bit is ‘0’, the LHIGH bit reads as ‘1’ if the local high limit was exceeded since the last clearing of the Status Register. The RHIGH bit reads as ‘1’ if the remote high limit was exceeded since the last clearing of the Status Register. If the AL/TH bit is ‘1’, the remote high limit and the local high limit are used to implement a THERM2 function. LHIGH reads as ‘1’ if the local temperature has exceeded the local high limit and remains greater than the local high limit less the value in the Hysteresis Register. The RHIGH bit reads as ‘1’ if the remote temperature has exceeded the remote high limit and remains greater than the remote high limit less the value in the Hysteresis Register. The LLOW and RLOW bits are not affected by the AL/TH bit. The LLOW bit reads as ‘1’ if the local low limit was exceeded since the last clearing of the Status Register. The RLOW bit reads as ‘1’ if the remote low limit was exceeded since the last clearing of the Status Register. The values of the LLOW, RLOW, and OPEN (as well as LHIGH and RHIGH when AL/TH is ‘0’) are latched and will read as ‘1’ until the Status Register is read or a device reset occurs. These bits are cleared by reading the Status Register, provided that the condition causing the flag to be set no longer exists. The values of BUSY, LTHRM, and RTHRM (as well as LHIGH and RHIGH when AL/TH is ‘1’) are not latched and are not cleared by reading the Status Register. They always indicate the current state, and are updated appropriately at the end of the corresponding ADC conversion. Clearing the Status Register bits does not clear the state of the ALERT pin; an SMBus alert response address command must be used to clear the ALERT pin. The TMP411 NORs LHIGH, LLOW, RHIGH, RLOW, and OPEN, so a status change for any of these flags from ‘0’ to ‘1’ automatically causes the ALERT pin to go low (only applies when the ALERT/THERM2 pin is configured for ALERT mode). Table 4. Status Register Format STATUS REGISTER (Read = 02h, Write = NA) BIT # D7 D6 D5 D4 D3 D2 D1 D0 BIT NAME BUSY LHIGH LLOW RHIGH RLOW OPEN RTHRM LTHRM POR VALUE 0(1) 0 0 0 0 0 0 0 (1) The BUSY bit will change to ‘1’ almost immediately (<< 100µs) following power-up, as the TMP411 begins the first temperature conversion. It will be high whenever the TMP411 is converting a temperature reading. |
Similar Part No. - TMP411 |
|
Similar Description - TMP411 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |