3 / 8 page ![]() B2-83 MGA SERIES 5 WATT DC/DC CONVERTERS DUAL OUTPUT MODELS MGA2805D MGA2812D MGA2815D PARAMETER CONDITIONS MIN TYP MAX MIN TYP MAX UNITS OUTPUT VOLTAGE +VOUT 11.88 12 12.12 14.85 15 15.15 VDC –VOUT –11.76 –12 –12.24 –14.70 –15 –15.30 OUTPUT CURRENT VIN = 16 to 40 VDC 0 ±208 333 0 ±167 267 mA OUTPUT POWER1 VIN = 16 to 40 VDC — — 5 — — 5 W OUTPUT RIPPLE 2 10 kHz - 2 MHz — 120 300 — 120 300 mV p-p LINE REGULATION +VOUT — 10 50 — 10 50 mV VIN = 16 to 40 VDC –VOUT — 40 180 — 40 180 LOAD REGULATION +VOUT (BALANCED) — 10 50 — 10 50 mV NO LOAD TO FULL –VOUT (BALANCED) — 50 200 — 50 200 CROSS REG.3 EFFECT ON –VOUT — 8 15 — 7 15= % INPUT VOLTAGE CONTINUOUS 16 28 40 16 28 40 VDC NO LOAD TO FULL TRANSIENT 50 ms — — 50 — — 50 V INPUT CURRENT NO LOAD — 33 63 — 38 63 FULL LOAD — — 267 — — 263 mA INHIBITED — 3 4 — 3 4 INPUT RIPPLE Tc = 25°C — 50 200 — 50 200 mA p-p 10 kHz - 10 MHz Tc = –55°C to +125°C — 75 300 — 75 300 EFFICIENCY 67 73 — 68 73 — % LOAD FAULT4 SHORT CIRCUIT POWER DISS. — 1.3 1.7 — 1.3 1.6 W RECOVERY — 10 30 — 10 30 ms STEP LOAD TRANSIENT –550 180 550 –600 180 600 mV pk RESPONSE 5, 6 RECOVERY 7 — 200 500 — 200 500 µs STEP LINE 16 – 40 – 16 VDC RESPONSE 8 TRANSIENT –500 100 500 –1500 200 1500 mV pk RECOVERY 7 — 0.8 2.0 — 1.6 4.0 ms START-UP OVERSHOOT 0 200 500 0 200 500 mV pk DELAY 0 10 30 0 10 30 ms INHIBIT PIN CURRENT UNIT INHIBITED — 2.5 4.0 — 2.5 4.0 mA CAPACITANCE INPUT TO OUTPUT — 50 — — 50 — pF CAPACITIVE LOAD — — 100 — — 100 µF Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified. Notes 1. Up to 4 watts, 80% of the total output power is available from either output providing the opposite output is simultaneously carrying 20% of the total output power. Each output must carry a minimum of 20% of the total output power in order to maintain regulation on the negative output. 2. Applies to both +Vout and –Vout 3. Cross regulation is specified for the following percentages of total output power: +PO = 20% and –PO = 80% to +PO =80% and –PO = 20% 4. Indefinite short circuit protection not guaranteed above 125°C (case). 5. Load transient transition time is >10 µs. 6. Response of either output when the load for each output is simultaneously transitioned from 25% to 50% to 25% of total output power (5 watts). 7. Recovery time is measured from application of the transient to the point at which Vout is within regulation. 8. Input step transition time is >10µs. AVAILABLE SOON , ASK YOUR INTERPOINT REP FOR INFORMA - TION |
Similar Part No. - MGA2805S |
|
Similar Description - MGA2805S |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |