Electronic Components Datasheet Search |
|
S29AL008D Datasheet(PDF) 20 Page - SPANSION |
|
S29AL008D Datasheet(HTML) 20 Page - SPANSION |
20 / 55 page 20 S29AL008D S29AL008D_00A3 June 16, 2005 Da t a S h ee t The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the Reset Com- mand, next. See also Requirements for Reading Array Data, on page 11 for more information. The table provides the read parameters, and Figure 13, on page 38 shows the timing diagram. Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’t care for this command. The reset command may be written between the sequence cycles in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to read- ing array data (also applies to programming in Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the op- eration is complete. The reset command may be written between the sequence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data (also applies to autoselect during Erase Suspend). If DQ5 goes high during a program or erase operation, writing the reset command returns the device to reading array data (also applies during Erase Suspend). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manu- facturer and devices codes, and determine whether or not a sector is protected. Table 5, on page 25 shows the address and data requirements. This method is an alternative to that shown in Table 4, on page 16, which is intended for PROM pro- grammers and requires VID on address bit A9. The autoselect command sequence is initiated by writing two unlock cycles, fol- lowed by the autoselect command. The device then enters the autoselect mode, and the system may read at any address any number of times, without initiating another command sequence. A read cycle at address XX00h retrieves the manufacturer code. A read cycle at address XX01h in word mode (or 02h in byte mode) returns the device code. A read cycle containing a sector address (SA) and the address 02h in word mode (or 04h in byte mode) returns 01h if that sector is protected, or 00h if it is un- protected. Refer to Table 2, on page 14 and Table 3, on page 15 for valid sector addresses. The system must write the reset command to exit the autoselect mode and return to reading array data. Word/Byte Program Command Sequence The system may program the device by word or byte, depending on the state of the BYTE# pin. Programming is a four-bus-cycle operation. The program com- mand sequence is initiated by writing two unlock write cycles, followed by the |
Similar Part No. - S29AL008D |
|
Similar Description - S29AL008D |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |