Electronic Components Datasheet Search |
|
MAX6660EVKIT Datasheet(PDF) 3 Page - Maxim Integrated Products |
|
|
MAX6660EVKIT Datasheet(HTML) 3 Page - Maxim Integrated Products |
3 / 7 page Note: Words in boldface are user-selectable features in the software. The program continually polls the device for new tem- perature data and status, and monitors for alert condi- tions. To disable the continuous polling of data, uncheck the Automatic Read checkbox. To change the THIGH and TLOW threshold comparison registers, select the appropriate data field and type in the new value. Pressing Enter after typing in the new values updates the internal registers. If an interrupt condition is generated by the tempera- ture crossing one of the alarm threshold levels, the message ALERT appears. To clear the interrupt, first eliminate the condition that caused it and then click on Read Alert. This action reads the Alert Response address, returns the value of the current MAX6660 slave address, and clears the interrupt. Note: The least-significant bit of the address is the read/write sta- tus bit; therefore, the address returned is 1 higher. Simple SMBus Commands There are two methods for communicating with the MAX6660: through the normal user-interface panel or through the SMBus commands available from pressing the MAXSMBUS button. A display pops up that allows the SMBus protocols, such as Read Byte and Write Byte, to be executed. To stop normal user-interface execution so that it does not override the manually set values, turn off the update timer that slaves the pro- gram to the conversion rate by unchecking the Automatic Read checkbox. The SMBus dialog boxes accept numeric data in bina- ry, decimal, or hexadecimal. Hexadecimal numbers should be prefixed by $ or 0x. Binary numbers must be exactly eight digits. Note: In places where the slave address asks for an 8- bit value, it must be the 7-bit slave address of the MAX6660 as determined by ADD0 and ADD1 with the last bit set to 1 for a read operation and zero for a write. Data Logging Check the Data Logging checkbox to activate data logging. Data logging saves temperature and status data to a text file that includes a time/date stamp next to each data point. If Automatic Read is enabled, data is sampled at 2Hz; however, the data is logged to the file only if either the temperature or status change. This slows the growth of the data-logging file. When Automatic Read is disabled, the data is logged each time the Read All button is clicked. To stop data log- ging, uncheck the Data Logging checkbox. Jumper and Switch Settings Two jumpers set the MAX6660 slave address. The default address is 1001 110 (ADD0 = ADD1 = VCC). JU1 corresponds to ADD0 and JU2 corresponds to ADD1; see Table 1 for a complete list of addresses. The MAX6660 must undergo a power-on reset for the new address to become effective. Note: The first 7 bits shown are the address. Y (bit 0) is the SMBus read/write bit. This bit is a 1 for a read oper- ation and zero for a write. A slide switch, S1, is provided as a means to force a power-on reset of the MAX6660. This switch disables power to the device. Fan Control The MAX6660 incorporates a closed-loop fan controller that regulates fan speed with tachometer feedback. It compares temperature data to fan threshold tempera- ture and gain setting, resulting in automatic fan control proportional to the remote-junction temperature. Figure 1 shows the registers that control the fan. The register values must be calculated for the selected fan. MAX6660 Evaluation System/Evaluation Kit _______________________________________________________________________________________ 3 SHUNT LOCATION MAX6660 ADDRESS JU1 (ADD0) JU2 (ADD1) 2-3 2-3 0011 000Y 2-3 Open 0011 001Y 2-3 1-2 0011 010Y Open 2-3 0101 001Y Open Open 0101 010Y Open 1-2 0101 011Y 1-2 2-3 1001 100Y 1-2 Open 1001 101Y 1-2 1-2 1001 110Y Table 1. JU1 and JU2 Shunt Settings for SMBus Address SHUNT LOCATION STBY PIN FUNCTION 1-2 Connected to VCC In operate mode 2-3 Connected to GND In standby mode Table 2. JU3 Shunt Settings for STBY |
Similar Part No. - MAX6660EVKIT |
|
Similar Description - MAX6660EVKIT |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |