Electronic Components Datasheet Search |
|
BMP280 Datasheet(PDF) 19 Page - Bosch Sensortec GmbH |
|
|
BMP280 Datasheet(HTML) 19 Page - Bosch Sensortec GmbH |
19 / 49 page Datasheet BMP280 Digital Pressure Sensor Page 19 BST-BMP280-DS001-19 | Revision 1.19 | January 2018 Bosch Sensortec © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. Not intended for publication. 3.8.2 Measurement rate in normal mode The following table explains which measurement rates can be expected in normal mode based on oversampling setting and tstandby. Table 14: typical output data Rate (ODR) in normal mode [Hz] Oversampling setting tstandby [ms] 0.5 62.5 125 250 500 1000 2000 4000 Ultra low power 166.67 14.71 7.66 3.91 1.98 0.99 0.50 0.25 Low power 125.00 14.29 7.55 3.88 1.97 0.99 0.50 0.25 Standard resolution 83.33 13.51 7.33 3.82 1.96 0.99 0.50 0.25 High resolution 50.00 12.20 6.92 3.71 1.92 0.98 0.50 0.25 Ultra high resolution 26.32 10.00 6.15 3.48 1.86 0.96 0.49 0.25 Table 15: Sensor timing according to recommended settings (based on use cases) Use case Mode Over- sampling setting osrs_p osrs_t IIR filter coeff. (see 3.3.3) Timing ODR [Hz] (see 3.8.2) BW [Hz] (see 3.3.3) handheld device low-power (e.g. Android) Normal Ultra high resolution ×16 ×2 4 tstandby = 62.5 ms 10.0 0.92 handheld device dynamic (e.g. Android) Normal Standard resolution ×4 ×1 16 tstandby = 0.5 ms 83.3 1.75 Weather monitoring (lowest power) Forced Ultra low power ×1 ×1 Off 1/min 1/60 full Elevator / floor change detection Normal Standard resolution ×4 ×1 4 tstandby = 125 ms 7.3 0.67 Drop detection Normal Low power ×2 ×1 Off tstandby = 0.5 ms 125 full Indoor navigation Normal Ultra high resolution ×16 ×2 16 tstandby = 0.5 ms 26.3 0.55 3.9 Data readout To read out data after a conversion, it is strongly recommended to use a burst read and not address every register individually. This will prevent a possible mix-up of bytes belonging to different measurements and reduce interface traffic. Data readout is done by starting a burst read from 0xF7 to 0xFC. The data are read out in an unsigned 20-bit format both for pressure and for temperature. It is strongly recommended to use the BMP280 API, available from Bosch |
Similar Part No. - BMP280 |
|
Similar Description - BMP280 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |