    # Series 171-173 Flat Pin Staked Flex Jumpers

    ## General Features

    - Combination of thin, flexible solid Copper conductors between layers of flame-retardant insulation.
    - Custom designs, materials, platings, sizes, and configurations are available upon request.
    - Aries reserves the right to change product specifications.

    ## Specifications

    ### Cable Details
    - **Insulation:**
    - Standard: White UL VW-1, Style 2643 Polyester (Mylar) adhesive.
    - High Temperature: Polyimide (Kapton) insulation with acrylic adhesive.
    - **Conductor:** Solid Copper, 26 gauge AWG equivalent.
    - **Housing:** Black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
    - **Pins:** Spring-tempered Copper Alloy 510.
    - **Plating Options:**
    - T: Matte Tin per ASTM-B545-97 over Nickel.
    - TL: Tin/Lead per SAE-AMS-P-81728 over Nickel.
    - **Current Rating:** 3 Amps
    - **Voltage Rating:** 300 Volts
    - **Dielectric Strength:** 2500 Volts/mil (standard), 4000 Volts/mil (high temp).
    - **Insulation Resistance:** 1000 MOhms (standard), 100,000 MOhms (high temp).
    - **Operating Temperature:** -67 to 257°F [-55 to 105°C]

    ## Ordering Information

    - **Number of Conductors:** 4-40
    - **Cable Length “L”:** Minimum 2.00 inches.
    - 2" = -002-
    - 2.5" = -002.5-
    - 2.25" = -002.25-
    - 2.125" = -002.125-
    - **Jumper Series:**
    - 171: Male Tin both ends
    - 172: Male Tin/Female Tin
    - 173: Female Tin both ends
    - **Optional Suffixes:**
    - P: Polarization stripe along one cable edge.
    - TL: Tin/Lead plating.
    - HT: High temperature cable insulation.

    ## Dimensions

    - “A”: Number of Conductors x .100 [2.54]
    - “B”: (Number of Conductors - 7) x .100 [2.54]
    - Suggested PCB hole size: .032 ± .002 [.81 ± .05] diameter.

    Datasheet Summary with AI

    # Series 171-173 Flat Pin Staked Flex Jumpers

    ## General Features

    - Combination of thin, flexible solid Copper conductors between layers of flame-retardant insulation.
    - Custom designs, materials, platings, sizes, and configurations are available upon request.
    - Aries reserves the right to change product specifications.

    ## Specifications

    ### Cable Details
    - **Insulation:**
    - Standard: White UL VW-1, Style 2643 Polyester (Mylar) adhesive.
    - High Temperature: Polyimide (Kapton) insulation with acrylic adhesive.
    - **Conductor:** Solid Copper, 26 gauge AWG equivalent.
    - **Housing:** Black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
    - **Pins:** Spring-tempered Copper Alloy 510.
    - **Plating Options:**
    - T: Matte Tin per ASTM-B545-97 over Nickel.
    - TL: Tin/Lead per SAE-AMS-P-81728 over Nickel.
    - **Current Rating:** 3 Amps
    - **Voltage Rating:** 300 Volts
    - **Dielectric Strength:** 2500 Volts/mil (standard), 4000 Volts/mil (high temp).
    - **Insulation Resistance:** 1000 MOhms (standard), 100,000 MOhms (high temp).
    - **Operating Temperature:** -67 to 257°F [-55 to 105°C]

    ## Ordering Information

    - **Number of Conductors:** 4-40
    - **Cable Length “L”:** Minimum 2.00 inches.
    - 2" = -002-
    - 2.5" = -002.5-
    - 2.25" = -002.25-
    - 2.125" = -002.125-
    - **Jumper Series:**
    - 171: Male Tin both ends
    - 172: Male Tin/Female Tin
    - 173: Female Tin both ends
    - **Optional Suffixes:**
    - P: Polarization stripe along one cable edge.
    - TL: Tin/Lead plating.
    - HT: High temperature cable insulation.

    ## Dimensions

    - “A”: Number of Conductors x .100 [2.54]
    - “B”: (Number of Conductors - 7) x .100 [2.54]
    - Suggested PCB hole size: .032 ± .002 [.81 ± .05] diameter.

    Part No.8-002.125-173PTLHT
    ManufacturerARIES
    Size248 Kbytes
    Pages2 pages
    DescriptionFlat Pin Staked Flex Jumpers
    Privacy Policy
    ALLDATASHEET.COM
    Does ALLDATASHEET help your business so far?  [ DONATE ] 

    About Alldatasheet   |   Advertisement   |   Datasheet Upload   |  Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com